Cache module status failed hp proliant что это
Перейти к содержимому

Cache module status failed hp proliant что это

  • автор:

HP proliant cache module failure

In our windows server environment, we often get the alert for HP servers that storage cache module has failed. What exactly is the function of cache module?

asked Feb 22, 2020 at 11:19
Soumendra Patra Soumendra Patra
23 1 1 silver badge 4 4 bronze badges

1 Answer 1

Unfortunately, you are neither mentioning a specific server model nor a specific controller, thus I’m assuming Smart Arrays here. HP/HPE Smart Array RAID controllers provide a battery-backed cache to e.g. temporarily store data before transferring them to disks. The cache is DRAM, thus it’s a lot faster than typical disk drives, and this speeds up e.g. write operations.

Let’s go one step back: Once a data write to the cache is completed, the cache must be able to protect the data in case of a power loss before the data has been transferred to the drives. This happens using a battery, and the battery is normally what fails after some time which leads to alerts or failure reports, because you might be on risk when using a non-battery-backed cache. If this does not apply for you, you should provide a specific failure message here.

The HP document Smart Array technology: advantages of battery-backed cache describes the details of the cache in detail.

answered Feb 22, 2020 at 12:33
356 1 1 silver badge 7 7 bronze badges

You must log in to answer this question.

  • hp-proliant
  • hp-smart-array
    The Overflow Blog
Related
Hot Network Questions

Subscribe to RSS

Question feed

To subscribe to this RSS feed, copy and paste this URL into your RSS reader.

Site design / logo © 2023 Stack Exchange Inc; user contributions licensed under CC BY-SA . rev 2023.10.27.43697

By clicking “Accept all cookies”, you agree Stack Exchange can store cookies on your device and disclose information in accordance with our Cookie Policy.

HP StoreOnce 4500 Backup — Cache module status — Failed

Добрый день. Имеется HP StoreOnce 4500 Backup на которые еженедельно бэкапятся данные.

HP StoreOnce 4500 Backup

Тип
HP StoreOnce 4500 Backup
Имя
HPCZ2511083J
Серийный номер
CZ2511083J
Версия программного обеспечения
3.12.1-1513.3

Сегодня обнаружили следующие ошибки:

В виду этого на сервер не могу скопировать бэкапы т.к. Nas постояно отключает сетевые папки.

component:superCapacitor, status:FAILED, location:IOCacheModule in storageController S/N:PCUUVC18S7X05I in PCI Slot 1 in server HPCZ2511083J, Message: The supercap has failed., Diagnostic message: Replace the supercap., uuid:50014380266AB5F0_IOC_1,50014380266AB5F0_BAT_1, eventName:SUPER_CAPACITOR_FAILED, eventId:001C0002, level:ALERT, category:SERVER, overallStatus:DEGRADED , name: ch_34303936-3538-5A43-3235-31313038334A , engine name: hpcz2511083j

component:IOCacheModule, status:FAILED, location:IOCacheModule in storageController S/N:PCUUVC18S7X05I in PCI Slot 1 in server HPCZ2511083J, Message: Write caching using the IO cache module has been temporarily disabled. This will cause degraded performance., Diagnostic message: Check the supercap status and if applicable the partner controller’s supercap status. If the supercap statuses are good, contact HP technical support for further assistance., uuid:50014380266AB5F0_IOC_1, eventName:IO_CACHE_MODULE_CACHE_DISABLED, eventId:00080003, level:ALERT, category:SERVER, overallStatus:DEGRADED , name: ch_34303936-3538-5A43-3235-31313038334A , engine name: hpcz2511083j

Сообщение ошибки в ILO:

POST Error: 1705-Slot X Drive Array — Please replace Cache Module Super-Cap. Caching will be enabled once Super-Cap has been replaced and charged.

Я так поняж нужно поменять батарейку модуля кэша

Скажите пожалуйста, в чем причина не исправности?

Можно ли парт номер или ссылку необходимой запчасти для замены.

Linux: Работа с RAID контроллером от HP

HP-Smart-Array-P410-RAID-Controller-Card-462919-001-wSFF-8087-mini_SAS-Battery-291402637154-4

Небольшая инструкцию по мониторингу и настройке Raid массива на Raid контроллерах HP под CentOS 6.7.

При наличии необходимых навыков эта инструкция подойдет под любой другой дистрибутив Linux.

1) Для начала убедимся, что у нас есть HP контроллер:

Смотрим в разрезе устройств на шине:
# lspci | grep -i RAID 06:00.0 RAID bus controller: Hewlett-Packard Company Smart Array G6 controllers (rev 01)
Устройств при загрузке:
# dmesg | grep -i RAID dracut: rd_NO_DM: removing DM RAID activation dracut: rd_NO_MD: removing MD RAID activation hpsa 0000:06:00.0: RAID device c4b3t0l0 added. scsi 4:3:0:0: RAID HP P410 3.66 PQ: 0 ANSI: 5
Или проверяем наличие символьного устройства hpilo.

Стоит уточнить, что на нескольких серверах, несмотря на наличие контроллера, символьного устройства не было.

#cat /proc/devices | grep hp 250 hpilo

1а) Более длинными способами, можно получить похожую картину:

Через smartctl:
# smartctl -i /dev/sda smartctl 5.43 2012-06-30 r3573 [x86_64-linux-2.6.32-573.18.1.el6.x86_64] (local build) Copyright (C) 2002-12 by Bruce Allen, http://smartmontools.sourceforge.net Vendor: HP Product: LOGICAL VOLUME Revision: 3.66 User Capacity: 1,499,830,990,848 bytes [1.49 TB] Logical block size: 512 bytes Logical Unit id: 0x600508b1001851395358343048380c00 Serial number: PACCR9SX4205 Device type: disk Local Time is: Thu Mar 3 14:27:52 2016 MSK Device does not support SMART
Через lshw:
# lshw -c disk *-disk:0 description: SCSI Disk product: LOGICAL VOLUME vendor: HP physical id: 0.0.0 bus info: scsi@4:0.0.0 logical name: /dev/sda version: 3.66 serial: PACCR9SX4205 size: 1396GiB (1499GB) capabilities: 15000rpm partitioned partitioned:dos configuration: ansiversion=5 logicalsectorsize=512 sectorsize=512 signature=0004650e *-disk:1 description: SCSI Disk product: LOGICAL VOLUME vendor: HP physical id: 0.0.1 bus info: scsi@4:0.0.1 logical name: /dev/sdb version: 3.66 serial: PACCR9SX4205 size: 1117GiB (1200GB) capabilities: 15000rpm partitioned partitioned:dos configuration: ansiversion=5 logicalsectorsize=512 sectorsize=512 signature=b294fbcd

2) Устанавливаем утилиту hpacucli.

Подключаем репозитарий HP:

Версию и разрядность системы необходимо подставить самостоятельно или написать общий шаблон.

cat spp.repo name=Service Pack for ProLiant baseurl=http://downloads.linux.hpe.com/repo/spp/rhel/6Server/x86_64/current/ enabled=1 gpgcheck=0 gpgkey=file:///etc/pki/rpm-gpg/GPG-KEY-ServicePackforProLiant
# yum install hpasmcli
Как вариант ставим RPM пакет HP, который соответствует вашей системе:
rpm -ivh http://downloads.linux.hpe.com/repo/spp/rhel/6Server/x86_64/current/hpacucli-9.40-12.0.x86_64.rpm warning: hpacucli-9.40-12.0.x86_64.rpm: Header V3 DSA/SHA1 Signature, key ID 2689b887: NOKEY Preparing. ########################################### [100%] 1:hpacucli ########################################### [100%] DOWNGRADE NOTE: To downgrade this application to any version prior to 9.10.x.x, the current RPM must be manually uninstalled using the "rpm -e" command before any prior versions can be installed. LOCKING NOTE: The locking mechanism starting with versions 9.10.X.X, are not compatible with prior versions of the applications. Therefore, mixing older and newer versions of the various applications (ACU, HPACUCLI, HPACUSCRIPTING) is not recommended.

3) Начало работа с hpacucli.

Проверяем статус контроллера:

Команда для проверки hpacucli controller all show status

Нормальное состояние контроллера должно отображаться так:
# hpacucli controller all show status Smart Array P410 in Slot 1 Controller Status: OK Cache Status: OK
С чем я сталкивался:
Отсутствие «Cache Status» говорит об отсутствии батареи у кеша.

В этом состоянии:
— по неподтвержденным данным замедленной работой контроллера, по сравнению с присутствием батареи;
— невозможностью расширения массива на лету, путем добавления дисков и т.п.

Error: This operation is not supported with the current configuration. Use the "show" command on devices to show additional details about the configuration. Reason: Transformation size zero
Батарея есть, но подлежит замене

Примерно тоже самое, что выше, но также есть риск потери данных кеша при внезапном отключении питания.
Ошибка выглядит так:

Smart Array P410 in Slot 1 Controller Status: OK Cache Status: Temporarily Disabled Battery/Capacitor Status: Failed (Replace Batteries/Capacitors)

2016-03-02 11-00-48

2016-03-02 11-04-24

2016-03-02 11-04-30

Пора заменить микрокод контроллера!

Ошибка намекает на несовместимость утилиты hpacucli с установленным микрокодом в контроллере. Вариант или подобрать утилиту или обновиться.

Smart Array P410 in Slot 1 CACHE STATUS PROBLEM DETECTED: The controller is disabled because the cache module is not attached. Please re-attach the cache module to re-enable the controller.

Процедура обновления достаточно простая, но как обычно существуют стандартные риски при обновлении любых рейд контроллеров и это тема для отдельной статьи.

Заинтересованным смотреть с Firmware CD Supplemental Update Smart Array P212, P410, P410i, P411, P712m, and P812. Обновление прошло на лету, изменения применяются после перезагрузки.

Это же обновление лечит появление ошибок вида:

hpsa 0000:06:00.0: CDB 2a000d407ca800000800000000000000 : hardware error
Перед обновлением собираем диагностическую информацию:

Данные будут доступны в «/tmp/diag_log.txt»

# hpssacli ctrl slot=1 diag file=/tmp/diag_log.txt Generating diagnostic report. done
А также текущую конфигурацию контроллера:
# hpssacli ctrl all show config Smart Array P410 in Slot 1 (sn: PACCR9SX4205 ) Port Name: 1I Port Name: 2I DL18xG6BP at Port 1I, Box 1, OK array A (SAS, Unused Space: 965488 MB) logicaldrive 1 (1.4 TB, RAID 5, Transforming, 49.22% complete) physicaldrive 1I:1:1 (port 1I:box 1:bay 1, SAS, 300 GB, OK) physicaldrive 1I:1:2 (port 1I:box 1:bay 2, SAS, 300 GB, OK) physicaldrive 1I:1:3 (port 1I:box 1:bay 3, SAS, 300 GB, OK) physicaldrive 1I:1:4 (port 1I:box 1:bay 4, SAS, 300 GB, OK) physicaldrive 1I:1:5 (port 1I:box 1:bay 5, SAS, 300 GB, OK) physicaldrive 1I:1:6 (port 1I:box 1:bay 6, SAS, 300 GB, OK) physicaldrive 1I:1:7 (port 1I:box 1:bay 7, SAS, 300 GB, OK) physicaldrive 1I:1:8 (port 1I:box 1:bay 8, SAS, 300 GB, OK) physicaldrive 1I:1:9 (port 1I:box 1:bay 9, SAS, 300 GB, OK) array B (SAS, Unused Space: 0 MB) logicaldrive 2 (1.1 TB, RAID 5, OK) physicaldrive 1I:1:10 (port 1I:box 1:bay 10, SAS, 600 GB, OK) physicaldrive 1I:1:11 (port 1I:box 1:bay 11, SAS, 600 GB, OK) physicaldrive 1I:1:12 (port 1I:box 1:bay 12, SAS, 600 GB, OK) Enclosure SEP (Vendor ID HP, Model DL18xG6BP) 248 (WWID: 50001C1071540013, Port: 1I, Box: 1) Expander 250 (WWID: 50001C1071540000, Port: 1I, Box: 1) SEP (Vendor ID PMCSIERA, Model SRC 8x6G) 249 (WWID: 50014380042FABEF)

Проверяем ранее собранную информацию. В моей диагностике видно, что запущено расширение массива (хотя оно было уже после накатки микрокода), что определенно вводит ограничение на обновление.

4) Настройка RAID с hpacucli.

Просмотр статусов логических дисков
#hpssacli controller slot=1 logicaldrive all show status logicaldrive 1 (1.4 TB, 5): OK logicaldrive 2 (1.6 TB, 5): OK

Если логический диск в «работе» статус это покажет.

Результат добавления дисков в массив:

#hpssacli ctrl slot=1 ld 1 add drives=1I:1:7,1I:1:8,,1I:1:9 #hpssacli controller slot=1 logicaldrive all show status logicaldrive 1 (1.4 TB, 5): Transforming, 49.13% complete logicaldrive 2 (1.1 TB, 5): OK
Просмотр статусов физических дисков

Один из дисков в режиме «скоро умрет».

#hpssacli controller slot=1 physicaldrive all show status physicaldrive 1I:1:1 (port 1I:box 1:bay 1, 300 GB): OK physicaldrive 1I:1:2 (port 1I:box 1:bay 2, 300 GB): OK physicaldrive 1I:1:3 (port 1I:box 1:bay 3, 300 GB): OK physicaldrive 1I:1:4 (port 1I:box 1:bay 4, 300 GB): OK physicaldrive 1I:1:5 (port 1I:box 1:bay 5, 300 GB): OK physicaldrive 1I:1:6 (port 1I:box 1:bay 6, 300 GB): OK physicaldrive 1I:1:9 (port 1I:box 1:bay 9, 600 GB): OK physicaldrive 1I:1:10 (port 1I:box 1:bay 10, 600 GB): Predictive Failure physicaldrive 1I:1:11 (port 1I:box 1:bay 11, 600 GB): OK physicaldrive 1I:1:12 (port 1I:box 1:bay 12, 600 GB): OK physicaldrive 1I:1:7 (port 1I:box 1:bay 7, 300 GB): OK physicaldrive 1I:1:8 (port 1I:box 1:bay 8, 300 GB): OK

Можем получить более детальную информацию:

#hpacucli ctrl all show config detail | more
Создание RAID массива
# Создание логического диска с RAID 0 включающего один физический диск hpacucli ctrl slot=1 create type=ld drives=1I:1:10 raid=0 # Создание логического диска с RAID 1 с двух физических дисков hpacucli ctrl slot=1 create type=ld drives=1I:1:10,1I:1:11 size=300 raid=1 # Создание логического диска с RAID 5 с тремя физическими дисками hpacucli ctrl slot=1 create type=ld drives=1I:1:10,1I:1:11,1I:1:12raid=5
Добавление дополнительного физического диска к логическому
hpacucli ctrl slot=1 ld 1 add drives=1I:1:10
Добавить запасной диск:
hpacucli ctrl slot=0 array all add spares=1I:1:10
Увеличение размера логического диска до указанного в size, после добавление нового физического
hpacucli ctrl slot=1 ld 1 modify size=500 forced

В моем случае ругнется и даст подсказку — нельзя делать диск меньше чес он сейчас.

Error: "size=500" is not a valid option for logicaldrive 1 Available options are: Max: 2288560 (Units in MB) Min: 1430350 (Units in MB) MaxMBR: Max. for MBR Partition Table (2097152 MB = 2 TB)

Свободное место можно взять из детального вывода «hpacucli ctrl all show config detail».
У меня после добавления свободно 0,9Tb

Array: A Interface Type: SAS Unused Space: 965488 MB Status: OK Array Type: Data
Работа с внутренним кешем
#Изменить пропорции кеширования: hpssacli ctrl slot=1 modify cacheratio=100/0 # Выключить/включить кэш hpacucli ctrl slot=1 modify dwc=disable hpacucli ctrl slot=1 modify dwc=enable

Категория: Администрирование

HP Smart Array — cache module status degraded

Hewlett Packard Enterprise

Статья-исследование. Докопаемся до источника проблемы и исправим её.

Как обычно ночью сработал мониторинг. Хорошо, что он сработал, даже отлично. Плохо что ночью.

На сервере HP Proliant DL360 Gen9 произошёл сбой. iLO выплюнуло ошибку, zabbix сервер поймал событие, сработал триггер аппаратной проблемы. По триггеру отправилось письмо, SMS и сработал скрипт, который отправил на Asterisk call-файл. И наша телефония дозвонилась до меня, ночью, зараза. Я не разобрал что там промямлил в трубку робот, но главная задача по поднятию админа была выполнена, как говорится, смотрите подробности в SMS.

Отказал кэш RAID контроллера Smart Array P440ar:

Cache Module Status — Degraded

hpe

На первый взгляд проблема не критичная, может ждать до утра. А утром начались проблемы, — сильная деградация по дискам. Больше суток ушло на то, чтобы переместить виртуальные машины с данного гипервизора на другой сервер. Я не замерял, но скорость переноса данных увеличилась раз в пять. Некоторые сервисы пришлось остановить.

Оказалось, что кэш RAID контроллера заметно оптимизирует работу массивов.

Поиск проблемы

Сервер уже не на гарантии, справляться с проблемой придётся самому.

Есть несколько возможных точек отказа:

  1. Проблема программная, возможно, из-за недавней прошивки RAID контроллера. Может помочь перезагрузка, сброс настроек RAID контроллера, выключение-включение кэша.
  2. Проблема с RAID контроллером. Может помочь прошивка или замена.
  3. Проблема с модулем кэша. Поможет разборка-сборка, замена модуля кэша.
  4. Проблема с проводами или контактами. Поможет разборка-сборка, переподключение батарейки, замена батарейки.
  5. Проблема с батарейкой. Поможет замена батарейки.

Первым делом перезагрузил сервер и iLO. Не помогло.

Проверил статус батарейки. Статус OK.

hpe

Непонятно, загрузимся в HPSSA (HP Smart Storage Administrator). Перезагружаем сервер, при загрузке нажимаем F9 для входа в System Utilities.

hpe

Выбираем System Configuration.

hpe

Выбираем проблемный контроллер: Embedded RAID 1: Smart Array P440ar Controller.

hpe

Выбираем Exit and launch HP Smart Storage Administrator (HPSSA).

hpe

Выбираем (уже выбрано) Smart Storage Administrator. Сюда же можно попасть выбрав F10 (Intelligent Provisioning) при загрузке, но нужно будет успеть переключить пункт в этом окне.

hpe

Дожидаемся загрузки Smart Storage Administrator.

hpe

Видно, что на RAID контроллере Smart Array P440ar светится предупреждение.

hpe

Текст ошибки здесь более информативный:

Smart Array P440ar in Embedded Slot has one or more cache module batteries/capacitors that are recharging. Caching operations such Expansion, Extension, and Migration are temporarily suspended until the batteries/capacitors are fully charged. Caching operations will automatically resume when charging is complete.

Получается, батарейка находится в процессе зарядки. Такое случается, если воткнуть разряженную батарейку. Ошибка пропадёт после полной зарядки. Но в моём случае батарейка уже давно установлена, ошибка сама не пропадает.

hpe

Server → Actions → Diagnose.

hpe

View Diagnostic Report.

hpe

Начинается сбор диагностических данных.

hpe

Кэш RAID контроллера отключён, других ошибок нет. Полистал отчёт, ничего особенного не обнаружил.

Посмотрим на кэш. Tools → Cache Manager → Controller Cache → Controller Cache Details.

hpe

  • Cache Status: Enabled, but not currently active.
  • Cache Status Details: Cache disabled; power source charging is low.
  • Battery/Capacitor Status: Recharging

Кэш отключён, т.к. батарейка заряжается, а уровень её заряда низок. Можно посмотреть больше деталей: View more details.

hpe

Более подробная информация нам особо не помогает, единственное, что интересно в нашем случае, это запись:

  • Enable Write Cache When Battery/Capacitor Not Present or Not Completely Charged: Disabled

В кэше контроллера есть опция, позволяющая включить кэш при отсутствии батарейки или при низком её заряде. Если бы сервер был боевым, если бы нам срочно нужно было наладить работу сервера, то включение этой опции нам бы очень помогло. Вот только включить эту опцию мы не можем, так, как кэш в настоящий момент отключён: There are no available actions. Печаль, но есть обходной манёвр.

Временное решение проблемы

Помимо кэша контроллера у каждого физического диска есть собственный кэш, который по умолчанию в RAID массивах отключён. Включим.

hpe

Smart Array P440ar → Actions → Configure → Modify Controller Settings.

hpe

Меняем галку Physical Drive Write Cache State на Enabled. Save Settings.

hpe

Controller Settings were successfully saved. Настройки сохранены. Как вы думаете, что сейчас произойдёт? Правильно, кэш RAID контроллера отключится. и все его предупреждения сбросятся.

Посмотрим на кэш. Tools → Cache Manager → Controller Cache → Controller Cache Details.

hpe

  • Cache Status: OK
  • Battery/Capacitor Status: OK

Даже батарейка перестала заряжаться. Но главное не это, появилась кнопка Modify Caching Settings, нажимаем.

hpe

Нас предупреждают, что включение кэша с плохой батарейкой приведёт к потере данных при внезапном отключении питания. Но всё же мы теперь можем, если очень захотим, включить опцию «Enable Write Cache When Battery/Capacitor Not Present or Not Completely Charged». Я не буду включать, срочного у меня ничего нет. Если сейчас снова отключить кэш физических дисков, то ошибка не вернётся до следующего цикла проверки батареи.

Становится понятно, что проблема в самой батарейке или в её проводах. Убедимся в этом. Перезагружаем сервер, жмём F9, во встроенных приложениях загружаем диагностический режим. Выполняем экспресс-проверку системы.

hpe

При проверке батарей: Основная — Заменить.

Решение проблемы

Меняем батарейку в сервере:

После замены батарейки снова загружаем диагностический режим и выполняем экспресс-проверку системы.

hpe

Проверка батареи : Основная — ОК. Ошибок нет.

Добавить комментарий